Message 207700 - Python tracker
Argument Clinic generates invalid code for optional parameter if there are no mandatory parameters except self. Example:
/*[clinic input]
zlib.Decompress.flush
self: self(type="compobject *")
[
length: uint
the initial size of the output buffer.
]
/
Return a bytes object containing any remaining decompressed data.
[clinic start generated code]*/
Generates:
...
switch (PyTuple_Size(args)) {
case 0:
if (!PyArg_ParseTuple(args, ":flush", ))
return NULL;
break;
...
Note a comma in PyArg_ParseTuple.